All publications
Conference presentation · KISM 2026

Measuring copper pad topography after CMP

After chemical mechanical polishing (CMP), the copper pads in this study sit just 1 to 2 nm below the surrounding dielectric. MetronDA segments the pads in Metron3D scans to measure their relative height, even when some pads are missing from the array.

1,248 images
analysed across eight datasets
0.08–0.16 nm
repeatability (3σ) of measured pad height
Metron3D height map showing an array of copper pads, with a height scale in nanometres.
Metron3D topography: 260 nm pads in a 3 × 3 µm field. Source: KISM 2026 presentation, slide 13.
Full reference and authors

Deep Learning-Based Segmentation for Robust High-Throughput 3D Probe Metrology of CMP Copper Pad Topography

Enrico Angioni, Hamish Rogers, Ali Hallal, Julien Baderot, Matthew Tedaldi, Daniel Haspel, Devin Giddings, Johann Foucher.

Presented by Enrico Angioni (Infinitesima).